*Registrieren *Impressum *Kontakt
*Deutsche Version*English Version  
Schnellsuche:
Nicht angemeldet. [Anmelden

Feldbeschreibung

Bildschirmformatierung Formatierung für Ausdruck

Radiofrequency-radiation exposure does not induce detectable leakage of albumin across the blood-brain barrier.

by McQuade JM, Merritt JH, Miller SA, Scholin T, Cook MC, Salazar A, Rahimi OB, Murphy MR, Mason PA
published in: Radiat Res 2009; 171 (5): 615 - 621


Exposure 1:
Main characteristics
frequency:915 MHz
type of field: electromagnetic field
Modulation
type of modulation: continuous wave (CW)
Exposure setup
exposure source/structure: TEM cell
exposure time pattern: continuous for 30 min
setup details: animals held in 14 cm x 14 cm x 6 cm Plexiglas cages inside the TEM cell
sham: sham exposure was performed
Exposure parameters
parameter:value:type:method:averaging mass:remark:
SAR 0.002 W/kg min value measured and calculated whole body 0.002, 0.02, 0.2, 2.0, 20 W/kg 
SAR 20 W/kg max value measured and calculated whole body 

Exposure 2:
Main characteristics
frequency:915 MHz
type of field: electromagnetic field
Modulation
type of modulation: pulsed (PW)
pulse width: 0.57 ms
duty factor/cycle0.91%
pulse repetition rate:16 Hz
Exposure setup
exposure source/structure: same setup as in Exposure 1
exposure time pattern: continuous for 30 min
sham: sham exposure was performed
Exposure parameters
parameter:value:type:method:averaging mass:remark:
SAR 0.0018 W/kg min value measured and calculated whole body 0.0018, 0.018, 0.18 W/kg 
SAR 0.18 W/kg max value measured and calculated whole body 

Exposure 3:
Main characteristics
frequency:915 MHz
type of field: electromagnetic field
Modulation
type of modulation: pulsed (PW)
pulse width: 0.57 ms
duty factor/cycle12.4%
pulse repetition rate:217 Hz
Exposure setup
exposure source/structure: same setup as in Exposure 1
exposure time pattern: continuous for 30 min
sham: sham exposure was performed
Exposure parameters
parameter:value:type:method:averaging mass:remark:
SAR 0.0025 W/kg min value measured and calculated whole body 0.0025, 0.025, 0.248, 2.48 W/kg 
SAR 2.48 W/kg max value measured and calculated whole body 


Reference article

Zu den Artikel-Basisdaten

Glossar: animals, CW, duty factor, electromagnetic field, exposure, Hz, MHz, pulsed, pulse repetition rate, pulse width, PW, SAR, sham exposure, TEM cell

© 1997 - 2013, Forschungszentrum für Elektro-Magnetische Umweltverträglichkeit (femu - RWTH Aachen).

Alle Rechte vorbehalten. Gestattet sind lediglich Abruf, Ansicht und Ausdruck, jedoch nicht Reproduktion, Veröffentlichung oder Weitergabe dieser Dokumente, ausschließlich für persönlichen und nichtkommerziellen Gebrauch, sofern (i) die Information in keiner Weise verändert und (ii) jedweder Copyright-Vermerk in allen Dokumenten nicht entfernt, sondern unverändert übernommen wird.

Die bereitgestellte Information stellt nicht den offiziellen Standpunkt des femu - RWTH Aachen dar, es sei denn, dies ist ausdrücklich vermerkt. Durch Abruf, Ansicht oder Ausdruck dieser Dokumente erklären Sie sich mit den im Kleingedruckten genannten Bedingungen ausdrücklich einverstanden.