Study type: Medical/biological study (experimental study)

Influence of variable electromagnetic field on the energy and germination capacity of Cannabis sativa L. subsp. culta Serebr med./bio.

Published in: 2018 Applications of Electromagnetics in Modern Techniques and Medicine (PTZE), Racławice, Poland. IEEE, 2018: 252-255; ISBN 978-1-5386-6937-2

Aim of study (acc. to author)

The effects of exposure of cannabis seeds to 50 Hz magnetic fields on germination should be investigated.

Background/further details

The cannabis seeds were exposed to a 50 mT or a 70 mT magnetic field for 30, 60, 90, 120, 150, 180, 210 and 240 minutes respectively. In addition, a control group without exposure was used. 100 seeds and 3 replicates were used for each condition.

Endpoint

Exposure

Exposure Parameters
Exposure 1: 50 Hz
Exposure duration: 30-240 minutes
Exposure 2: 50 Hz
Exposure duration: 30-240 minutes

Exposure 1

Main characteristics
Frequency 50 Hz
Type
Exposure duration 30-240 minutes
Exposure setup
Exposure source
Setup a solenoid measuring 480 mm in length and 60 mm in diameter
Parameters
Measurand Value Type Method Mass Remarks
magnetic flux density 50 mT - - - -

Exposure 2

Main characteristics
Frequency 50 Hz
Type
Exposure duration 30-240 minutes
Exposure setup
Exposure source
Parameters
Measurand Value Type Method Mass Remarks
magnetic flux density 70 mT - - - -

Exposed system:

Methods Endpoint/measurement parameters/methodology

Investigated system:
Time of investigation:
  • after exposure

Main outcome of study (acc. to author)

Exposure to the magnetic field of 70 mT resulted in significantly higher numbers of correctly developed seedlings in all exposure durations compared to the control group. In the case of exposure to the 50 mT magnetic field, only some exposure durations (90, 120 and 240 min) showed a significantly higher number of correctly developed seedlings compared to the control group.
There were no significant differences in germination capacity and energy capacity after exposure to a magnetic field for either 50 mT or 70 mT compared to the control group.
The authors conclude that exposure to 50 Hz magnetic fields might result in a decrease of developmental defects in cannabis seedlings.

Study character: